By Pass Rotameter

Our range of products include by pass rotameter for chemical process industries, flowtech bypass rotameters, bypass glass tube rotameter, air flow meter rotameter, rotameters and flow meter and by pass glass tube rotameter.

By Pass Rotameter for Chemical Process Industries

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Tube Body ConstructionGlass
Model Name/NumberFMIPL-BPRM-
Range Ability60000 LPH
Usage/ApplicationIndustrial Use
BrandFlowtech
ApplicationIndustrial
Country of OriginMade in India
Pressure Ratings10 Bar
Temperature Ratings- 20 Deg C to 250 Deg C
Accuracy2% FSD
DESPRICTION :

Flowtech Make By-pass Rotameters are suitable for flow rate measurement in 2’’ NB or 24” higher size pipes. The instrument is simple in construction and reliable in flow rate indication. The complete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter as indicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

PRINCIPLE OF BY-PASS ROTAMETER :

 By Pass Rotameter is an inference type Rotameter & fixed Orifice in a pipeline.
 Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate in the main Pipe line. Because of this differential pressure a branch of flow moves through by- pass line provided across the orifice plate from upstream side to down -stream side of Orifice Plate.
 An additional range orifice plate is provided in the by-pass line which is designed such that flow through by –pass line (through range orifice plate) flows in proportion with the flow through main pipe line (Main Orifice Plate).  Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

BY-PASS METERING COMPONENTS:

The By-pass flow meter consists of a mainline Orifice plate, a set of Orifice Flanges Or a carrier ring, a flow meter, range Orifice, Bypass piping with Isolation Valves.

 Mainline Orifice Plate: - The purpose of the mainline orifice plate is to create the pressure differential. As the flow rate varies across this mainline orifice, the pressure differential across this plate also varies and it is this variation, which makes the meter function.

 Orifice Flanges / Carrier Ring: - Orifice flanges / carrier rings serve two functions. First, they hold the mainline orifice plate in the proper position within the pipeline. Secondly they channel a portion of the flow out of the high-pressure side of the orifice and return it again to the low-pressure side. This function may be accomplished with other than flange taps. The Bypass piping may be connected directly to the pipeline in the form of pipe taps, radius taps OR vena contract taps.

 Variable Area Flow Meter: - As discussed above, a flow meter (Glass Tube Rotameter) is placed in the Bypass piping to measure the bypass flow.

 Range Orifice: - The range orifice is a small orifice placed in the bypass piping either before OR after the flow meter. This orifice is sized so that the total pressure drop through the bypass-piping equals the pressure differential across the mainline orifice  

Specifications:
  • Flanged OR Screwed
  • Suitable for larger pipeline of 50 NB to 600 NB
  • The Flowrate through the Rotameters is proportional to the pressure drop across the orifice plate
  • Available in SS-316/ SS-304/P.P material
  • Accuracy=2% FSDHigh & Low flow Switches on request.
Yes! I am interested

Flowtech Bypass Rotameters

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Flow range100-1000 LPH
Tube Body ConstructionGlass
Line size25 mm
Body materialGlass tube
Model Name/NumberFMIPL-BPRM-
Usage/ApplicationIndustrial Use
Process fluidAir
End connectionFlanged
Scale typeCustom scale
BrandFlowtech
Flowtech Make By-pass Rota meters are suitable for flow rate measurement in 2’’ NB or highersize pipes. The instrument is simple in construction and reliable in flow rate indication. Thecomplete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter asindicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

Design Features:
  • Easy to Maintain
  • On-Line installation
  • Most economical, low cost
  • Pipe size -40 NB to 600 NB
  • Connections can be rotated 360 degree at 90 degree.
  • Transparent acrylics sheets.??? Scale length of 180-200 mm.
  • Low flow & High flow alarm switch on request.
  • Available in complete MOC in S.S 304 & S.S 316

Principle Of By-pass Rotameter:
  • By Pass Rota meter is an inference type Rota meter & fixed Orifice in a pipeline.
  • Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate inthe main Pipe line. Because of this differential pressure a branch of flow moves throughby- pass line provided across the orifice plate from upstream side to down -stream sideof Orifice Plate.
  • An additional range orifice plate is provided in the by-pass line which is designed suchthat flow through by –pass line (through range orifice plate) flows in proportion with theflow through main pipe line (Main Orifice Plate).
  • Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

PERFORMANCE:
Accuracy : +/- 2% F.S.D.
Repeatability : 0.5 %
Rangeability : 5:1 for 50” WC D.P., 7:1 for 100” & 150” WC D.P., 10 : 1 for 200” & 40 0” WC D.P.
Scale length : 180-200 mm
Pressure Ratings : Maximum
Operating Pressure is 15 Kg/Cm2.
Temperature Ratings : Maximum
Operating Temperature rating is 121 o C for Gas services And 93o C for Liquid services.
Connections : Flanged.
Enclosure : IP 55 OR IP 65 on reques
Yes! I am interested

Bypass Glass Tube Rotameter

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Model Name/NumberFMIPL-BPRM
Range Ability60000 LPH
Usage/ApplicationIndustrial
BrandFlowtech
Country of OriginMade in India
MaterialStainless Steel
Accuracy+-1 %
Maximum Operating Pressure15 Kg/Cm2
Repeatability0.5 %

DESPRICTION :

Flowtech Make By-pass Rotameters are suitable for flow rate measurement in 2’’ NB or 24” higher size pipes. The instrument is simple in construction and reliable in flow rate indication. The complete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter as indicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

PRINCIPLE OF BY-PASS ROTAMETER :

 By Pass Rotameter is an inference type Rotameter & fixed Orifice in a pipeline.
 Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate in the main Pipe line. Because of this differential pressure a branch of flow moves through by- pass line provided across the orifice plate from upstream side to down -stream side of Orifice Plate.
 An additional range orifice plate is provided in the by-pass line which is designed such that flow through by –pass line (through range orifice plate) flows in proportion with the flow through main pipe line (Main Orifice Plate).  Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

BY-PASS METERING COMPONENTS:

The By-pass flow meter consists of a mainline Orifice plate, a set of Orifice Flanges Or a carrier ring, a flow meter, range Orifice, Bypass piping with Isolation Valves.

 Mainline Orifice Plate: - The purpose of the mainline orifice plate is to create the pressure differential. As the flow rate varies across this mainline orifice, the pressure differential across this plate also varies and it is this variation, which makes the meter function.

 Orifice Flanges / Carrier Ring: - Orifice flanges / carrier rings serve two functions. First, they hold the mainline orifice plate in the proper position within the pipeline. Secondly they channel a portion of the flow out of the high-pressure side of the orifice and return it again to the low-pressure side. This function may be accomplished with other than flange taps. The Bypass piping may be connected directly to the pipeline in the form of pipe taps, radius taps OR vena contract taps.

 Variable Area Flow Meter: - As discussed above, a flow meter (Glass Tube Rotameter) is placed in the Bypass piping to measure the bypass flow.

 Range Orifice: - The range orifice is a small orifice placed in the bypass piping either before OR after the flow meter. This orifice is sized so that the total pressure drop through the bypass-piping equals the pressure differential across the mainline orifice  

Specifications:

  • Flanged OR Screwed
  • Suitable for larger pipeline of 50 NB to 600 NB
  • The Flowrate through the Rotameters is proportional to the pressure drop across the orifice plate
  • Available in SS-316/ SS-304/P.P material
  • Accuracy=2% FSDHigh & Low flow Switches on request.
Yes! I am interested

Air Flow Meter Rotameter

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Flow range25-250 LPH
Line size25 mm
Body materialGlass tube
Usage/ApplicationIndustrial
Process fluidWater
End connectionFlanged
Scale typeDirect reading
ApplicationIndustrial
BrandFlowtech
MountingIn line
DESPRICTION :

Flowtech Make By-pass Rotameters are suitable for flow rate measurement in 2’’ NB or 24” higher size pipes. The instrument is simple in construction and reliable in flow rate indication. The complete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter as indicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

PRINCIPLE OF BY-PASS ROTAMETER :

 By Pass Rotameter is an inference type Rotameter & fixed Orifice in a pipeline.
 Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate in the main Pipe line. Because of this differential pressure a branch of flow moves through by- pass line provided across the orifice plate from upstream side to down -stream side of Orifice Plate.
 An additional range orifice plate is provided in the by-pass line which is designed such that flow through by –pass line (through range orifice plate) flows in proportion with the flow through main pipe line (Main Orifice Plate).  Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

BY-PASS METERING COMPONENTS:

The By-pass flow meter consists of a mainline Orifice plate, a set of Orifice Flanges Or a carrier ring, a flow meter, range Orifice, Bypass piping with Isolation Valves.

 Mainline Orifice Plate: - The purpose of the mainline orifice plate is to create the pressure differential. As the flow rate varies across this mainline orifice, the pressure differential across this plate also varies and it is this variation, which makes the meter function.

 Orifice Flanges / Carrier Ring: - Orifice flanges / carrier rings serve two functions. First, they hold the mainline orifice plate in the proper position within the pipeline. Secondly they channel a portion of the flow out of the high-pressure side of the orifice and return it again to the low-pressure side. This function may be accomplished with other than flange taps. The Bypass piping may be connected directly to the pipeline in the form of pipe taps, radius taps OR vena contract taps.

 Variable Area Flow Meter: - As discussed above, a flow meter (Glass Tube Rotameter) is placed in the Bypass piping to measure the bypass flow.

 Range Orifice: - The range orifice is a small orifice placed in the bypass piping either before OR after the flow meter. This orifice is sized so that the total pressure drop through the bypass-piping equals the pressure differential across the mainline orifice  

Specifications:
  • Flanged OR Screwed
  • Suitable for larger pipeline of 50 NB to 600 NB
  • The Flowrate through the Rotameters is proportional to the pressure drop across the orifice plate
  • Available in SS-316/ SS-304/P.P material
  • Accuracy=2% FSDHigh & Low flow Switches on request.
Yes! I am interested

Rotameters And Flow Meter

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Flow range100-1000 LPH
Tube Body ConstructionGlass
Body materialGlass tube
Model Name/NumberFMIPL-BPRM-108
Range Ability50000 LPH
Usage/ApplicationIndustrial Use
Process fluidWater
End connectionFlanged
Scale typeCustom scale
MaterialSS,MS
Flowtech Make By-pass Rota meters are suitable for flow rate measurement in 2’’ NB or highersize pipes. The instrument is simple in construction and reliable in flow rate indication. Thecomplete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter asindicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

Design Features:
  • Easy to Maintain
  • On-Line installation
  • Most economical, low cost
  • Pipe size -40 NB to 600 NB
  • Connections can be rotated 360 degree at 90 degree.
  • Transparent acrylics sheets.??? Scale length of 180-200 mm.
  • Low flow & High flow alarm switch on request.
  • Available in complete MOC in S.S 304 & S.S 316

Principle Of By-pass Rotameter:
  • By Pass Rota meter is an inference type Rota meter & fixed Orifice in a pipeline.
  • Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate inthe main Pipe line. Because of this differential pressure a branch of flow moves throughby- pass line provided across the orifice plate from upstream side to down -stream sideof Orifice Plate.
  • An additional range orifice plate is provided in the by-pass line which is designed suchthat flow through by –pass line (through range orifice plate) flows in proportion with theflow through main pipe line (Main Orifice Plate).
  • Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

PERFORMANCE:
Accuracy : +/- 2% F.S.D.
Repeatability : 0.5 %
Rangeability : 5:1 for 50” WC D.P., 7:1 for 100” & 150” WC D.P., 10 : 1 for 200” & 40 0” WC D.P.
Scale length : 180-200 mm
Pressure Ratings : Maximum
Operating Pressure is 15 Kg/Cm2.
Temperature Ratings : Maximum
Operating Temperature rating is 121 o C for Gas services And 93o C for Liquid services.
Connections : Flanged.
Enclosure : IP 55 OR IP 65 on reques
Yes! I am interested

By Pass Glass Tube Rotameter

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Range Ability50000 LPH
Usage/ApplicationIndustrial
ApplicationIndustrial
BrandFlotech
Country of OriginMade in India
Pressure Ratings10 Bar
Temperature Ratings- 20 Deg C to 250 Deg C
ConnectionsFlanged or Screwed
Accuracy2% FSD
Pipe SizeMax. 450 NB

Our range of By Pass Glass Tube Rotameter is widely acknowledged for their accuracy, reliability and long service life. Available in different ranges, our range comes with various accessories such as DP regulator, panel mounting clamps and high & low flow alarms. These products from our side are suitable for purging or low flow rate of air or liquid measurement.

Features:

  • Heavy duty design
  • Easy to replace
  • Powder coated

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:

  • Suitable for larger pipeline of 50 NB to 600 NB
  • The Flowrate through the Rotameters is proportional to the pressure drop across the orifice plate
  • Available in SS-316/ SS-304/P.P material
  • Accuracy=2% FSD
  • High & Low flow Switches on request

 

Yes! I am interested

By-Pass Glass Tube Rotameter

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Range Ability60000 LPH
Usage/ApplicationWater
BrandFlowtech
Country of OriginMade in India
Scale LengthMax. 200 mm
Accuracy2% FSD.
MaterialSS / PTFE
Material GradeSS316
Repeatability0.5 %
Maximum Operating Pressure15 Kg/Cm2

DESPRICTION :

Flowtech Make By-pass Rotameters are suitable for flow rate measurement in 2’’ NB or 24” higher size pipes. The instrument is simple in construction and reliable in flow rate indication. The complete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter as indicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

PRINCIPLE OF BY-PASS ROTAMETER :

 By Pass Rotameter is an inference type Rotameter & fixed Orifice in a pipeline.
 Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate in the main Pipe line. Because of this differential pressure a branch of flow moves through by- pass line provided across the orifice plate from upstream side to down -stream side of Orifice Plate.
 An additional range orifice plate is provided in the by-pass line which is designed such that flow through by –pass line (through range orifice plate) flows in proportion with the flow through main pipe line (Main Orifice Plate).  Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

BY-PASS METERING COMPONENTS:

The By-pass flow meter consists of a mainline Orifice plate, a set of Orifice Flanges Or a carrier ring, a flow meter, range Orifice, Bypass piping with Isolation Valves.

 Mainline Orifice Plate: - The purpose of the mainline orifice plate is to create the pressure differential. As the flow rate varies across this mainline orifice, the pressure differential across this plate also varies and it is this variation, which makes the meter function.

 Orifice Flanges / Carrier Ring: - Orifice flanges / carrier rings serve two functions. First, they hold the mainline orifice plate in the proper position within the pipeline. Secondly they channel a portion of the flow out of the high-pressure side of the orifice and return it again to the low-pressure side. This function may be accomplished with other than flange taps. The Bypass piping may be connected directly to the pipeline in the form of pipe taps, radius taps OR vena contract taps.

 Variable Area Flow Meter: - As discussed above, a flow meter (Glass Tube Rotameter) is placed in the Bypass piping to measure the bypass flow.

 Range Orifice: - The range orifice is a small orifice placed in the bypass piping either before OR after the flow meter. This orifice is sized so that the total pressure drop through the bypass-piping equals the pressure differential across the mainline orifice  

Specifications:

  • Flanged OR Screwed
  • Suitable for larger pipeline of 50 NB to 600 NB
  • The Flowrate through the Rotameters is proportional to the pressure drop across the orifice plate
  • Available in SS-316/ SS-304/P.P material
  • Accuracy=2% FSDHigh & Low flow Switches on request.
Yes! I am interested

Flow Measuring Instrument

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 8550 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Usage/ApplicationWater
Model Name/NumberFMIPL-BPRM
BrandFlowtech
Application MediaWater
MaterialStainless Steel
Process Pressure2 kg/cm2
Accuracy2% FSD
Temperature Range150 Deg C
Line Size150 NB
Country of OriginMade in India
DESPRICTION :

Flowtech Make By-pass Rotameters are suitable for flow rate measurement in 2’’ NB or 24” higher size pipes. The instrument is simple in construction and reliable in flow rate indication. The complete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter as indicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

PRINCIPLE OF BY-PASS ROTAMETER :

 By Pass Rotameter is an inference type Rotameter & fixed Orifice in a pipeline.
 Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate in the main Pipe line. Because of this differential pressure a branch of flow moves through by- pass line provided across the orifice plate from upstream side to down -stream side of Orifice Plate.
 An additional range orifice plate is provided in the by-pass line which is designed such that flow through by –pass line (through range orifice plate) flows in proportion with the flow through main pipe line (Main Orifice Plate).  Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

BY-PASS METERING COMPONENTS:

The By-pass flow meter consists of a mainline Orifice plate, a set of Orifice Flanges Or a carrier ring, a flow meter, range Orifice, Bypass piping with Isolation Valves.

 Mainline Orifice Plate: - The purpose of the mainline orifice plate is to create the pressure differential. As the flow rate varies across this mainline orifice, the pressure differential across this plate also varies and it is this variation, which makes the meter function.

 Orifice Flanges / Carrier Ring: - Orifice flanges / carrier rings serve two functions. First, they hold the mainline orifice plate in the proper position within the pipeline. Secondly they channel a portion of the flow out of the high-pressure side of the orifice and return it again to the low-pressure side. This function may be accomplished with other than flange taps. The Bypass piping may be connected directly to the pipeline in the form of pipe taps, radius taps OR vena contract taps.

 Variable Area Flow Meter: - As discussed above, a flow meter (Glass Tube Rotameter) is placed in the Bypass piping to measure the bypass flow.

 Range Orifice: - The range orifice is a small orifice placed in the bypass piping either before OR after the flow meter. This orifice is sized so that the total pressure drop through the bypass-piping equals the pressure differential across the mainline orifice  

Specifications:
  • Flanged OR Screwed
  • Suitable for larger pipeline of 50 NB to 600 NB
  • The Flowrate through the Rotameters is proportional to the pressure drop across the orifice plate
  • Available in SS-316/ SS-304/P.P material
  • Accuracy=2% FSDHigh & Low flow Switches on request.
Yes! I am interested

Industrial Flow Meter

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 8550 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
Meter Technologyglass tube
Fluid TypeWater
Line Size25 mm
End ConnectionFlanged
Output Signal4–20 mA
Display TypeAnalog
DisplayLocal
Application MediaWater
MaterialSS
Accuracy2% FSD.
Flowtech Make By-pass Rota meters are suitable for flow rate measurement in 2’’ NB or highersize pipes. The instrument is simple in construction and reliable in flow rate indication. Thecomplete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter asindicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

Design Features:
  • Easy to Maintain
  • On-Line installation
  • Most economical, low cost
  • Pipe size -40 NB to 600 NB
  • Connections can be rotated 360 degree at 90 degree.
  • Transparent acrylics sheets.
  • Scale length of 180-200 mm.
  • Low flow & High flow alarm switch on request.
  • Available in complete MOC in S.S 304 & S.S 316

Principle Of By-pass Rotameter:
  • By Pass Rota meter is an inference type Rota meter & fixed Orifice in a pipeline.
  • Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate inthe main Pipe line. Because of this differential pressure a branch of flow moves throughby- pass line provided across the orifice plate from upstream side to down -stream sideof Orifice Plate.
  • An additional range orifice plate is provided in the by-pass line which is designed suchthat flow through by –pass line (through range orifice plate) flows in proportion with theflow through main pipe line (Main Orifice Plate).
  • Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.
Yes! I am interested

Bypass Type Rotameter

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
ModelBPR-062
Tube Body ConstructionGlass
Model Name/NumberFMIPL-BPRM
Range Ability60000 LPH
BrandFlowtech
Country of OriginMade in India
Accuracy2% FSD
Repeatability0.5 %
Scale Length180 mm
Pressure RatingsMaximum Operating Pressure is 15 Kg/Cm2
DESPRICTION :

Flowtech Make By-pass Rotameters are suitable for flow rate measurement in 2’’ NB or 24” higher size pipes. The instrument is simple in construction and reliable in flow rate indication. The complete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter as indicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

PRINCIPLE OF BY-PASS ROTAMETER :

 By Pass Rotameter is an inference type Rotameter & fixed Orifice in a pipeline.
 Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate in the main Pipe line. Because of this differential pressure a branch of flow moves through by- pass line provided across the orifice plate from upstream side to down -stream side of Orifice Plate.
 An additional range orifice plate is provided in the by-pass line which is designed such that flow through by –pass line (through range orifice plate) flows in proportion with the flow through main pipe line (Main Orifice Plate).  Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

BY-PASS METERING COMPONENTS:

The By-pass flow meter consists of a mainline Orifice plate, a set of Orifice Flanges Or a carrier ring, a flow meter, range Orifice, Bypass piping with Isolation Valves.

 Mainline Orifice Plate: - The purpose of the mainline orifice plate is to create the pressure differential. As the flow rate varies across this mainline orifice, the pressure differential across this plate also varies and it is this variation, which makes the meter function.

 Orifice Flanges / Carrier Ring: - Orifice flanges / carrier rings serve two functions. First, they hold the mainline orifice plate in the proper position within the pipeline. Secondly they channel a portion of the flow out of the high-pressure side of the orifice and return it again to the low-pressure side. This function may be accomplished with other than flange taps. The Bypass piping may be connected directly to the pipeline in the form of pipe taps, radius taps OR vena contract taps.

 Variable Area Flow Meter: - As discussed above, a flow meter (Glass Tube Rotameter) is placed in the Bypass piping to measure the bypass flow.

 Range Orifice: - The range orifice is a small orifice placed in the bypass piping either before OR after the flow meter. This orifice is sized so that the total pressure drop through the bypass-piping equals the pressure differential across the mainline orifice  

Specifications:
  • Flanged OR Screwed
  • Suitable for larger pipeline of 50 NB to 600 NB
  • The Flowrate through the Rotameters is proportional to the pressure drop across the orifice plate
  • Available in SS-316/ SS-304/P.P material
  • Accuracy=2% FSDHigh & Low flow Switches on request.
Yes! I am interested

BY-Pass Type Rotameter

Get Best Quote
Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
  • Product Image
Request Callback

₹ 10800 / PieceGet Latest Price

Product Brochure
Minimum Order Quantity1 Piece
BrandFlowtech
Range Ability60000 LPH
Usage/ApplicationWater
ApplicationIndustrial
Country of OriginMade in India
Larger Pipeline SizeMax. 450 NB
MaterialSS-316/ SS-304/P.P
Accuracy2% FSD
DESPRICTION :

Flowtech Make By-pass Rotameters are suitable for flow rate measurement in 2’’ NB or 24” higher size pipes. The instrument is simple in construction and reliable in flow rate indication. The complete assembly consists of carrier rings/flanged taps, bypass line and a Rota meter as indicator. The orifice plate dimension is based on BS/ISO- 5167 specification.

PRINCIPLE OF BY-PASS ROTAMETER :

 By Pass Rotameter is an inference type Rotameter & fixed Orifice in a pipeline.
 Differential pressure (DP) is created in the main pipe line by providing an Orifice Plate in the main Pipe line. Because of this differential pressure a branch of flow moves through by- pass line provided across the orifice plate from upstream side to down -stream side of Orifice Plate.
 An additional range orifice plate is provided in the by-pass line which is designed such that flow through by –pass line (through range orifice plate) flows in proportion with the flow through main pipe line (Main Orifice Plate).  Hence by measuring the flow from By-pass Line we can estimate the flow through Main pipe Line.

BY-PASS METERING COMPONENTS:

The By-pass flow meter consists of a mainline Orifice plate, a set of Orifice Flanges Or a carrier ring, a flow meter, range Orifice, Bypass piping with Isolation Valves.

 Mainline Orifice Plate: - The purpose of the mainline orifice plate is to create the pressure differential. As the flow rate varies across this mainline orifice, the pressure differential across this plate also varies and it is this variation, which makes the meter function.

 Orifice Flanges / Carrier Ring: - Orifice flanges / carrier rings serve two functions. First, they hold the mainline orifice plate in the proper position within the pipeline. Secondly they channel a portion of the flow out of the high-pressure side of the orifice and return it again to the low-pressure side. This function may be accomplished with other than flange taps. The Bypass piping may be connected directly to the pipeline in the form of pipe taps, radius taps OR vena contract taps.

 Variable Area Flow Meter: - As discussed above, a flow meter (Glass Tube Rotameter) is placed in the Bypass piping to measure the bypass flow.

 Range Orifice: - The range orifice is a small orifice placed in the bypass piping either before OR after the flow meter. This orifice is sized so that the total pressure drop through the bypass-piping equals the pressure differential across the mainline orifice  

Specifications:
  • Flanged OR Screwed
  • Suitable for larger pipeline of 50 NB to 600 NB
  • The Flowrate through the Rotameters is proportional to the pressure drop across the orifice plate
  • Available in SS-316/ SS-304/P.P material
  • Accuracy=2% FSDHigh & Low flow Switches on request.
Yes! I am interested

Contact Us

Nilesh Shah (Director)
Flowtech Measuring Instrument Private Limited
900/2/B, NR. Pakona Engineering, Gidc Makarpura, Vadodara - 390010, Gujarat, India

Get Directions
Send Email
08048265405
Share: