Electromagnetic Flow Meters

Description:

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:

  • Nominal Dia (mm) : 15 to 1500
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Process Temperature : Max. 150C
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer/TC END / BSP
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD.
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 30 meters
  • Installation : Inline Flange Type.

Electromagnetic Digital Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Nominal Diameter25 mm
BrandFlowtech
Pipe Size1 Inch
MaterialStainless Steel
Packaging TypeWooden Cages
DisplayDigital
Model Name/NumberFlowMag 900
Power Supply230 V AC / 24 V DC
ConnectivityRS485
Connection25 NB
Accuracy+- 0.5% FSD
Flow Range1 - 10 m3/hr
Process TemperatureMax. 150 Deg C
Country of OriginMade in India
Process PressureMax. 25 kg/cm 2
Application MediaWater
Usage/ApplicationETP

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150 Deg C
  • Nominal Dia (mm): 15 to 1400mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Digital Water Flow Meter Applications

Water flow meters can measure cold water, hot water, clean water, dirty water and slurries


Indian Market

Indian States: Telangana, Tamil Nadu, Mizoram, Jharkhand, Arunachal Pradesh, Manipur, Tripura, Kerala, Gujarat, Maharashtra, Madhya Pradesh, Rajasthan, Uttar Pradesh, Orissa, Uttarakhand, Assam, Sikkim, Nagaland, Chhattisgarh, Tamil Nadu, Jammu and Kashmir, Haryana, West Bengal, Goa, Delhi, Bihar, Punjab, etc.

International Market

Asian Countries: Indonesia, Thailand, Malaysia, Singapore, Nepal, Bangladesh, etc
Europe: France, Poland, Spain, etc
Gulf Countries: Saudi Arabia, United Arab Emirates,etc..

Electromagnetic Water Flow Meter

Request Callback

₹ 45000 / Piece Get Latest Price

Product Brochure
Nominal Diameter200 mm
BrandFlowtech
Pipe Size8 Inches
MaterialMild Steel
Usage/ApplicationWater
Model Name/NumberFlowMag900
DisplayDigital
Connection8" (200 NB)
Flow Range56 - 565 m3/hr
Accuracy0.5% FSD
Country of OriginMade in India
MakeFLOWTECH

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 

Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150 Deg C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF 
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • Meters Installation: Inline Flange Type.

Water Magnetic Flow Meter

Request Callback

₹ 28800 / Piece Get Latest Price

Product Brochure
Measurement PrincipleElectromagnetic
Line Size6 inch
Media TypeWater
Application MediaWater
Usage/ApplicationETP
Output SignalRelay, HART, 4-20mA, RS485, Pulse
Accuracy+- 0.5% oF FSD
TypeFlow meter
BrandFlowtech
ModelEMFM-0135
DisplayDigital
Automation GradeManual
MaterialStainless Steel
Model Name/NumberFMIPL-EMF-108
ConnectionFlanged
ConnectivityUSB, RS485
Meter TypeElectronics
Flow Range100 - 2250 m3/hr
FeaturesBatch Controller, Telemetry, Flameproof, Data Logging
Environment Temp.100 Deg C
Electrode MaterialSS.316. SS.316L, HASTALLOY-C
Communication4 - 20 mA / RS 485 MODBUS / PULSE
ConditionNew
Process TemperatureMax. 150 Deg C
Nominal Diameter15 - 1000 mm
Material Grade of ConstructionMS, SS 304, SS 316 & SS 316L

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.

The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.




Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries


Specifications:

  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1000mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer/BSP
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Water Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Size1 inch / 25 mm
Usage/ApplicationIndustrial
ModelEMFM-0203
DisplayRemote, Local
BrandFlowtech
Process TemperatureMax. 150 Deg C
Accuracy+- 1%
Process PressureMax. 25 kg/cm2
Repeatability0.3%

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Water Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:
  • Nominal Dia (mm) : 15 to 1500NB
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Optional: ±0.5% FSD
  • Display : 2 Line Alfa Numeric LCD
  • Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters
  • Installation : Inline Flange Type.

Digital Water Flow Meter For Borewell As Per CGWA

Request Callback

₹ 27000 / Piece Get Latest Price

Product Brochure
Size6 Inch
Usage/ApplicationIndustrial
MaterialStainless Steel
Line Size15 NB TO 1300 NB
Application MediaWater
Model Name/NumberElectromagnetic Flow Meter
ModelFMIPL-EMFM-108
Display TypeDigital
DisplayDigital
BrandFlowtech
Warranty1 Year
Country of OriginMade in India

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1300mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Magnetic Water Flow Meter

Request Callback

₹ 36000 / Piece Get Latest Price

Product Brochure
Size6 Inch
Usage/ApplicationIndustrial
Line Size150 NB (6")
MaterialStainless Steel
BrandFlowtech
Model Name/NumberFlowMag 900
Display TypeDigital
DisplayDigital
Warranty1 Year
Flow range31 to 318 m3/hr
Accuracy+-0.5% FSD
Country of OriginMade in India
Process PressureMax. 25 kg/cm2
Process TemperatureMax. 150 Deg C
Optional+-0.5% FSD

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Magnetic Water Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:
  • Nominal Dia (mm): 15 to 1200mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Repeatability: 0.3%Display : 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65Protection Class for Transmitter : IP 65
  • Cable Length for Remote: 25 meters
  • Installation: Inline Flange Type Magnetic Water Flow Meter.

Digital Flowmeters Effluent Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Measurement PrincipleElectromagnetic
Media TypeWater
Line Size4 inch (100 mm)
BrandFlowtech
Application MediaWater
Accuracy0.5% FSD
Output Signal4-20mA, Pulse, RS485, Relay, HART
MaterialStainless Steel
Operating Temperature150 Deg C (Max)
Display TypeDigital
Operating Pressure25 kg/cm2 (Max)
FeaturesFlameproof, Telemetry, Batch Controller, Data Logging

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Remote Type Digital Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Measurement PrincipleElectromagnetic
Media TypeWater
Line Size8 inch (200 mm)
Application MediaWater
Accuracy0.5%
Output Signal4-20mA, Pulse, Relay, HART, RS485
TypeFlow Meter
Size (Inch)0.5 - 2 Inch, 4 - 6 Inch
ApplicationIndustrial
MaterialMid Steel
Operating TemperatureAmbient
BrandFlowtech
DisplayDigital
Model Name/NumberFMIPL-EMF-108
Flow Range0.9 - 9 m3/hr
ConnectionFlanged
Operating Pressure5 kg/cm2
Display TypeRemote
FeaturesData Logging, Telemetry, Flameproof, Batch Controller
Maximum Temperature (Degree Celsius)150 Deg C
Country of OriginMade in India

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Effluent Water Digital Flow Meter

Request Callback

₹ 18900 / Piece Get Latest Price

Product Brochure
Measurement PrincipleElectromagnetic
Media TypeWater
Line Size6 inch (150 mm)
Size6 Inch
MaterialStainless Steel
Usage/ApplicationIndustrial
DisplayDigital
Output SignalRelay, Pulse, HART, 4-20mA, RS485
Accuracy0.5 %
ModelEMFM-0712
BrandFlowtech
FeaturesData Logging, Telemetry, Batch Controller, Flameproof

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
    Flowtech Make Electromagnetic Flow Boiler Feed Water Meter Are Intended For Measuring Flow Of Electrically Conductive Liquids In Closed Pipe Lines Where The Magnetic Flux Permeates The Entire Cross Sectional Area Of The Liquids Flow. Electromagnetic Flow Meters Measure Electromotive Forces To Determine Liquids Velocity Using Faraday’s Law Of Electromagnetic Induction And Compute The Flow Rate Using Equation Of Conductive Liquids Having Minimum Conductivity Of 5 Micro Siemens / Cm And Are Relatively Immune To The Effects Of Temperature , Pressure , Viscosity & Density Of The Flowing Liquid.

Technical Detail:
  • Nominal Dia (mm) : 15 to 1600mm
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC 
  • Output : Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 30 meters
  • Installation : Inline Flange Type.

Digital Water Flow Meter For Borewell

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Measurement PrincipleElectromagnetic
Media TypeWater
Line Size1 inch
Application MediaWater
Pipe Size1 Inch
Usage/ApplicationWater
Output SignalRelay, Pulse, HART, RS485, 4-20mA
Accuracy0.5% FSD
BrandFlowtech
Size (Inch)0.5 - 2 Inch, 2 - 4 Inch
ApplicationIndustrial
MaterialStainless Steel
DisplayDigital
Model Name/NumberFMIPL-EMF
Connection25 NB
Flow Range0.9 - 9 M3/HR
FeaturesData Logging, Telemetry, Flameproof, Batch Controller
Maximum Pressure (Bar)1 - 25 Bar
Maximum Temperature (Degree Celsius)150 Deg C
Country of OriginMade in India

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.

Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries


Specifications:

  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150 Deg C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Digital Water Flow Meter Applications

Water flow meters can measure cold water, hot water, clean water, dirty water and slurries


Indian Market

Indian States: Telangana, Tamil Nadu, Mizoram, Jharkhand, Arunachal Pradesh, Manipur, Tripura, Kerala, Gujarat, Maharashtra, Madhya Pradesh, Rajasthan, Uttar Pradesh, Orissa, Uttarakhand, Assam, Sikkim, Nagaland, Chhattisgarh, Tamil Nadu, Jammu and Kashmir, Haryana, West Bengal, Goa, Delhi, Bihar, Punjab, etc.

International Market

Asian Countries: Indonesia, Thailand, Malaysia, Singapore, Nepal, Bangladesh, etc
Europe: France, Poland, Spain, etc
Gulf Countries: Saudi Arabia, United Arab Emirates,etc..

Digital Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Measurement PrincipleElectromagnetic
ApplicationWater (Raw; Potable; Treated)
Media TypeWater
Line Size15 NB to 1500 NB
Accuracy+- 1% FSD Optional: +-0.5% FSD.
Output Signal4-20mA Analog
Application MediaWater
Operating Temperature50 Deg C
Flow range(Min-Max)3 - 1271 m3/hr, As per connection size.
BrandFlowtech
Display TypeDigital
Operating Pressure25 Kg/cm2
FeaturesData Logging, Batch Controller, Flameproof, Telemetry
Country of OriginMade in India

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Digital Water Flow Meter Applications

Water flow meters can measure cold water, hot water, clean water, dirty water and slurries


Indian Market

Indian States: Telangana, Tamil Nadu, Mizoram, Jharkhand, Arunachal Pradesh, Manipur, Tripura, Kerala, Gujarat, Maharashtra, Madhya Pradesh, Rajasthan, Uttar Pradesh, Orissa, Uttarakhand, Assam, Sikkim, Nagaland, Chhattisgarh, Tamil Nadu, Jammu and Kashmir, Haryana, West Bengal, Goa, Delhi, Bihar, Punjab, etc.

International Market

Asian Countries: Indonesia, Thailand, Malaysia, Singapore, Nepal, Bangladesh, etc
Europe: France, Poland, Spain, etc
Gulf Countries: Saudi Arabia, United Arab Emirates,etc..

Sanitary Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaWater
BrandFlowtech
Operating TemperatureAmbient
Line Size15 NB to 600 NB
Flow Range0.9 - 9 m3/hr
Accuracy+- 1% FSD
Display TypeRemote
Operating Pressure25 Kg/Cm2
MaterialMS / SS
Country of OriginMade in India
Optional+-0.5% FSD

Minimum order quantity: 1 Piece

Flowtech Make Sanitary Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
  • Technical Detail:
    • Nominal Dia (mm): 15 to 1000mm
    • Material of Construction: MS, SS 304, SS 316 & SS 316L
    • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Process Pressure: Max. 25 kg/cm2
    • Process Temperature: Max. 150C
    • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Accuracy: ± 1%
    • FSD Optional: ±0.5% FSD.
    • Repeatability: 0.3%
    • Display: 2 Line Alfa Numeric LCD
    • Display Version: Integral /Remote
    • Display Unit: Standard Unit in M3, Litre
    • Protection Class for Transmitter: IP 65Cable Length for Remote : 25 meters.Installation : Inline Flange Type.
    .

Online Effluent Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Size1 inch / 25 mm
TypeWoltman Water Meter
Application MediaWater
MaterialStainless Steel
DisplayDigital
Model Name/NumberFlowMaf900
Accuracy+- 1% FSD
Process TemperatureMax. 150 Deg C
BrandFlowtech
Repeatability0.3%
Country of OriginMade in India
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150 Deg C
  • Nominal Dia (mm): 15 to 1400mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Digital Water Flow Meter Applications

Water flow meters can measure cold water, hot water, clean water, dirty water and slurries


Indian Market

Indian States: Telangana, Tamil Nadu, Mizoram, Jharkhand, Arunachal Pradesh, Manipur, Tripura, Kerala, Gujarat, Maharashtra, Madhya Pradesh, Rajasthan, Uttar Pradesh, Orissa, Uttarakhand, Assam, Sikkim, Nagaland, Chhattisgarh, Tamil Nadu, Jammu and Kashmir, Haryana, West Bengal, Goa, Delhi, Bihar, Punjab, etc.

International Market

Asian Countries: Indonesia, Thailand, Malaysia, Singapore, Nepal, Bangladesh, etc
Europe: France, Poland, Spain, etc
Gulf Countries: Saudi Arabia, United Arab Emirates,etc..

Industrial Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaWater
Line Size15 NB TO 600 NB
BrandFlowtech
Process TemperatureMax. 150 Deg C
Material GradeSS316

Minimum order quantity: 1 Piece

Description:

  • Flowtech Make Industrial Flow Meter Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.


Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Technical Detail:

  • Nominal Dia (mm) : 15 to 600
  • Material of Construction : MS, SS 304, SS 316 SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD.
  • Repeatability : 0.3%
  • Display : 2 Line Alfa Numeric LCD
  • Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA / RS 485
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters.
  • Installation : Inline Flange Type.

Hot Water Flow Meters

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Size0.5 - 2 Inch
Usage/ApplicationIndustrial
BrandFlowtech
ApplicationIndustrial
DisplayDigital
Accuracy+-1 %
Process TemperatureMax. 150 Deg C
Protection Class for TransmitterIP 65
Cable Length for Remote10 meters
Repeatability0.3%
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Hot Water Flow Meters are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:
  • Nominal Dia (mm) : 15 to 600NB
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • FSD Optional: ±0.5% FSD
  • Display : 2 Line Alfa Numeric LCD
  • Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65.

Digital Water Electromagnetic Flow Meters

Request Callback

₹ 36000 / Piece Get Latest Price

Product Brochure
BrandFlowtech
Pipe Size6 Inches
MaterialMild Steel
Usage/ApplicationWater
DisplayDigital
Model Name/NumberFlowMag900
Connection150 NB (6")
Flow Range31 - 318 m3/hr
Accuracy0.5% FSD
Country of OriginMade in India
MakeFLOWTECH

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 

Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150 Deg C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF 
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • Meters Installation: Inline Flange Type.

Electromagnetic Water Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Pipe Size1 Inch
MaterialMild Steel
DisplayDigital
Model Name/NumberFlowMag900
Connection25 NB Flanged
Flow Range0.9 - 9 m3/hr
Accuracy0.5% FSD.
Process TemperatureMax. 150 C
Country of OriginMade in India
Nominal Diameter25 NB
Process PressureMax. 25 kg/cm2
MakeFlowtech
Application MediaWater
Usage/ApplicationETP

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 

Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faradays law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150 Deg C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF 
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • Meters Installation: Inline Flange Type.

Electromagnetic Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
BrandFlowtech
MaterialStainless Steel
Pipe Size12 Inches
Application MediaWater
Usage/ApplicationWater
TypeFlow meter
DisplayDigital
Model Name/NumberFMIPL-EMF-108
ConnectionFlanged
Flow Range100 - 2250 m3/hr
Accuracy+- 0.5% oF FSD
Flange Size400 NB ASA 150 # RF
Process TemperatureMax. 150 Deg C
Power Supply230 VAC X 5 Amp / 24 V DC
Max. Pressure25 KG/CM2
Line Size15 to 1200 mm Available
IP RatingIP-65
Environment Temp.100 Deg C
Electrode MaterialSS.316. SS.316L, HASTALLOY-C
Communication4 - 20 mA / RS 485 MODBUS / PULSE
Country of OriginMade in India
Cable Length for Remote30 meters
Nominal Diameter15 to 1200 mm
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Flowmeter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Specifications:

  • Nominal Dia (mm) : 15 to 1200mm
  • Material of Construction : MS, SS 304, SS 316 SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Process Temperature : Max. 150 Deg C
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 30 meters
  • Installation : Inline Flange Type.

Electromagnetic Water Flowmeter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
BrandFlowtech
Application MediaAny Liquid
Pipe Size6 Inches
MaterialMS
TypeFlow meter
DisplayDigital
Power Supply230 V AC / 24 V DC
Model Name/NumberFMIPL-EMF-108
ConnectionFlanged
Accuracy0.5% FSD, 0.5%
Process TemperatureMax. 150 Deg C
Power Supply (V)230 VAC X 5 Amp
Country of OriginMade in India
Nominal Diameter15 to 1400 mm
Process PressureMax. 25 kg/cm 2
Usage/ApplicationETP

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1400mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Digital Water Flow Meter Applications

Water flow meters can measure cold water, hot water, clean water, dirty water and slurries


Indian Market

Indian States: Telangana, Tamil Nadu, Mizoram, Jharkhand, Arunachal Pradesh, Manipur, Tripura, Kerala, Gujarat, Maharashtra, Madhya Pradesh, Rajasthan, Uttar Pradesh, Orissa, Uttarakhand, Assam, Sikkim, Nagaland, Chhattisgarh, Tamil Nadu, Jammu and Kashmir, Haryana, West Bengal, Goa, Delhi, Bihar, Punjab, etc.

International Market

Asian Countries: Indonesia, Thailand, Malaysia, Singapore, Nepal, Bangladesh, etc
Europe: France, Poland, Spain, etc
Gulf Countries: Saudi Arabia, United Arab Emirates,etc..

Electromagnetic Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
BrandFlowtech
Pipe Size1 Inch
MaterialStainless Steel
TypeMagnetic Flow meter
Operating Temperature50 Deg C
Accuracy0.5% FSD
DisplayDigital
Display TypeDigital
Model Name/NumberFMIPL-EMF-108
Power Supply230 V AC / 24 V DC
Connection1 "ASA 150 # RF (25 NB)
Flow Range0.9 - 9 m3/hr
Operating Pressure5 kg/cm2
Ambient Temp60 Deg C
Process TemperatureMax. 150 Deg C
Country of OriginMade in India
Nominal Diameter15 to 1800 mm Available
Process PressureMax. 25 kg/cm 2
Application MediaWater
Usage/ApplicationETP

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 

Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1800mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF 
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • Meters Installation: Inline Flange Type.

Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Measurement PrincipleElectromagnetic
BrandFlowtech
Nominal Diameter25 mm
Line Size1 inch
ApplicationWater (Raw; Potable; Treated)
Media TypeWater
Application MediaWater
Pipe Size1 Inch
Output Signal4-20mA
DisplayDigital
Flow range0.9 - 9 m3/hr
FeaturesTelemetry
Accuracy+/-1% FSD Optional +/-0.5% FSD.
Repeatability0.3%

Minimum order quantity: 1 Piece

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:

  • Nominal Dia (mm) : 15 to 1600mm
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Process Temperature : Max. 150C
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters
  • Installation : Inline Flange Type.

Battery Operated Digital Flow Meter Remote Type

Request Callback

₹ 22500 / Piece Get Latest Price

Product Brochure
Application MediaWater
BrandFlowtech
DisplayDigital
ModelEMFMBO-099
ApplicationIndustrial
Operating Temperature90 Deg C
MaterialSS
Accuracy0.25%
Display TypeDigital
Fluid Temp150 Deg C
Country of OriginMade in India
Temperatureup to 150 Deg C

Minimum order quantity: 1 Piece

Flowtech Battery Operator Electromagnetic Flow Meter operation principle is based on measuring electromotive force induced in electrically conductive liquid when it moves in magnetic field. The magnetic field is furnished in the flow sensor's inner channel by a special electromagnetic system.

Inductive electromotive force (EMP) E is proportional to the mean flow velocity v, distance between the electrodes d (which is equal to the sensor's inner diameter), and magnetic field strength E = v ×d×B×k.

Specifications:

  • Nominal Dia (mm) : 15 to 1200 mm
  • Material of Construction : MS, SS 304, SS 316 SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Process Temperature : Max. 150C
  • End Connection : Flange/Wafer
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Installation : Inline Flange Type.

Water Flow Rate Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaAny Liquid, Water
DisplayLocal, Remote
MaterialStainless Steel
Accuracy+- 1 %
BrandFlowtech
Repeatability0.3%
Process TemperatureMax. 150 C
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Water Flow Rate Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:
  • Nominal Dia (mm): 15 to 600NB
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer/TC END
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • FSD Optional: ±0.5% FSD
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 10 meters
  • Installation: Inline Flange Type.

Digital Milk Flow Meter

Request Callback

₹ 36000 / Piece Get Latest Price

Product Brochure
Pipe Size12 Inches
Usage/ApplicationWater
MaterialStainless Steel
Application MediaAny Liquid, Water
DisplayLocal
Power Supply230 V AC / 24 V DC
Accuracy+- 1% FSD
Process TemperatureMax. 150 Deg C
BrandFlowtech
Country of OriginMade in India
Repeatability0.3%
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1400mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Digital Water Flow Meter Applications

Water flow meters can measure cold water, hot water, clean water, dirty water and slurries


Indian Market

Indian States: Telangana, Tamil Nadu, Mizoram, Jharkhand, Arunachal Pradesh, Manipur, Tripura, Kerala, Gujarat, Maharashtra, Madhya Pradesh, Rajasthan, Uttar Pradesh, Orissa, Uttarakhand, Assam, Sikkim, Nagaland, Chhattisgarh, Tamil Nadu, Jammu and Kashmir, Haryana, West Bengal, Goa, Delhi, Bihar, Punjab, etc.

International Market

Asian Countries: Indonesia, Thailand, Malaysia, Singapore, Nepal, Bangladesh, etc
Europe: France, Poland, Spain, etc
Gulf Countries: Saudi Arabia, United Arab Emirates,etc..

Water Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
BrandFlowtech
DisplayDigital
ModelEMFM-0634
Accuracy+- 1%
Process TemperatureMax. 150 Deg C
Repeatability0.3%
Process PressureMax. 25 kg/cm2

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Water Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:
  • Nominal Dia (mm) : 15 to 600NB
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • FSD Optional: ±0.5% FSD
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters
  • Installation : Inline Flange Type.

Magnetic Flow Meter

Request Callback

₹ 18900 / Piece Get Latest Price

Product Brochure
Pipe Size12 Inches
Usage/ApplicationWater
BrandFlowtech
Application MediaAny Liquid, Water
DisplayDigital
Accuracy+- 1% FSD
Process TemperatureMax. 150 Deg C
Country of OriginMade in India
Process PressureMax. 25 kg/cm2

Minimum order quantity: 1 Piece

Description:
  • Flowtech Make Electro Magnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Technical Detail:
  • Nominal Dia (mm) : 15 to 1200 NB
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Process Temperature : Max. 150C
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters
  • Installation : Inline Flange Type.

Digital PVC Electromagnetic Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
BrandFlowtech
Application MediaWater
MaterialPlastic Body
ModelEMF-0130
ApplicationIndustrial
Pressure Ratings2 Bar
Temperature Ratings- 20 Deg C to 50 Deg C
Accuracy- 2% F.S.D

Minimum order quantity: 1 Piece

Product Description

We are leading manufacturer of Low weight Low cost PVC Electromagnetic Flow Meter from India.

Product Specification

 

Meter SizeDN 25 to DN 100
Flow Through PipeHDPE, PVC
ElectrodesHastelloy, SS 316, SS.316L,Tantalam
Flow Meter BodyPVC
Flange MaterialPVC
End ConnectionFLANGE, TC, SMS UNION, 
Input Supply110 to 230 V Ac.50 Hz
Power Supply of field CoilsPlused Dc
Min Conductivity5 cm 

FLOWTECH Make PVC Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.
 
Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:

  • Nominal Dia (mm) : 15 to 100
  • Material of Construction : PVC
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Process Pressure : Max. 5 kg/cm2
  • Process Temperature : Max. 50C
  • Flow Tube Material : PVC
  • End Connection : Flange/Wafer
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters
  • Installation : Inline Flange Type.

Plastic PVC Electromagnetic Flow Meter

Request Callback

₹ 14400 / Unit Get Latest Price

Product Brochure
BrandFlowtech
Application MediaWater
MaterialPVC
ModelEMF-126
ApplicationIndustrial
Packaging TypeWooden Box

Minimum order quantity: 1 Unit

Product Description

We are leading manufacturer of Low weight Low cost PVC Electromagnetic Flow Meter from India.

Product Specification

 

Meter SizeDN 25 to DN 100
Flow Through PipePVC
ElectrodesHastelloy, SS 316, SS.316L,Tantalam
Flow Meter BodyPVC
Flange MaterialPVC
End ConnectionFLANGE, TC, SMS UNION, 
Input Supply110 to 230 V Ac.50 Hz
Power Supply of field CoilsPlused Dc
Min Conductivity5 cm 

FLOWTECH Make PVC Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.
 
Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:

  • Nominal Dia (mm) : 15 to 100
  • Material of Construction : PVC
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Process Pressure : Max. 5 kg/cm2
  • Process Temperature : Max. 50C
  • End Connection : Flange/Wafer
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters
  • Installation : Inline Flange Type.

    Water Pipe Flow Meter

    Request Callback

    ₹ 18000 / Piece Get Latest Price

    Product Brochure
    Usage/ApplicationDomestic
    BrandFlowtech
    Application MediaWater
    Operating Pressure25 Kg/Cm2
    Line Size15 NB To 600 NB
    DisplayRemote, Local
    Repeatability0.3%

    Minimum order quantity: 1 Piece

    Flowtech Make Electromagnetic Water Pipe Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

    Working principle:
    • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

    Technical Detail:
    • Nominal Dia (mm): 15 to 600NB
    • Material of Construction: MS, SS 304, SS 316 & SS 316L
    • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Flow Tube Material: SS 316
    • End Connection: Flange/Wafer/TC END
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
    • FSD Optional: ±0.5% FSD
    • Display : 2 Line Alfa Numeric LCD
    • Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC & 24 VDC
    • Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65
    • Protection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.

    Digital Water Flow Meters

    Request Callback

    ₹ 16200 / Piece Get Latest Price

    Product Brochure
    Application MediaWater
    BrandFlowtech
    Operating Temperature150 Deg C
    Accuracy+- 1% FSD Optional: +-0.5% FSD.
    Display TypeDigital
    Nominal Diameter15 to 600 mm
    Process PressureMax. 25 kg/cm 2
    Process TemperatureMax. 150 deg C

    Minimum order quantity: 1 Piece

    Product Description:

    The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

    Operating Principle:

    The electromagnetic flow meter is an instrument for measuring the flow of conductive fluid using Faraday's electromagnetic induction law, and consequently the fluid must be electrically conductive. As illustrated below a magnetic field with density B - perpendicular to the direction of flow - stretches across a fluid flowing within an electrically isolated pipe.

    The magnetic flux will induce a voltage difference (E) that can be measured between two electrodes arranged perpendicular to the direction of flow and themagnetic field.The voltage is proportionalto the velocity (V) ofthe fluid. 


    (1) E = B x D x V x k [Volt] where E is the voltage that is induced between the two electrodes B is the magnetic flux density D is the distance between the two electrodes V is the fluid velocity k is a dimensionless constant.
    The flow of the fluid Q (M³/Sec.) is given by the following formula: (2) Q = π x D2 x V / 4 => V = 4 / (π x D2) where π :is the constant pi (= 22/7) D : is the internaldiameter V :is the fluid velocity The combination of above formulas (1) and (2) gives the following formula E = K x B x D x Q x 4 / (π x D x D) = 4 K x B x Q / (π x D) Evidently the voltage E is proportional to the actual flow.

    Measurement: 

    Electromagnetic flow meters may have eitherDirect Current(DC) orAlternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due toelectro-chemical polarization between the electrodes and the fluid. The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of bothDC and AC systems.
    A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.

    Technical Detail:

    • Material of Construction: MS, SS 304, SS 316 & SS 316L
    • Electrode Material: SS 316, SS 316L, Hastelloy ‘C’, & Tantalum
    • Nominal Dia (mm) : 15 to 600mm
    • Flow Tube Material: SS 316
    • End Connection: Flange/Wafer/TC END
    • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Accuracy : ± 1%
    • FSD Optional: ±0.5% FSD
    • Repeatability: 0.3%
    • Display: 2 Line Alfa Numeric LCD
    • Display Version: Integral /Remote
    • Display Unit: Standard Unit in M3, Litre
    • Power Supply: 230 VAC, 110 VAC & 24 VDC
    • Output: Std. 4 – 20 mA
    • Protection Class for Sensor: IP 65
    • Protection Class for Transmitter: IP 65
    • Cable Length for Remote: 10 meters
    • Installation: Inline Flange Type.

    Sanitary Magnetic Flow Meter

    Request Callback

    ₹ 18000 / Piece Get Latest Price

    Product Brochure
    Pipe Size1 Inch
    MaterialMild Steel
    Usage/ApplicationWater
    BrandFlowtech
    DisplayDigital
    Application MediaAny Liquid, Water
    Model Name/NumberFlowMag900
    Connection25 NB
    ConnectivityRS485, RS232, USB
    Flow Range0.9 - 9 m3/hr
    Accuracy0.5% FSD
    Country of OriginMade in India
    Process PressureMax. 25 kg/cm2
    Material GradeSS304

    Minimum order quantity: 1 Piece

    Flowtech Make Sanitary Magnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

    Working Principle:
    • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

    Applications:
    • Scientific laboratory
    • Research centres
    • Chemical industries
    Specifications:
    • Nominal Dia (mm): 15 to 600
    • Material of Construction : MS, SS 304, SS 316 & SS 316L
    • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Process Pressure : Max. 25 kg/cm2
    • Process Temperature : Max. 150C
    • Flow Tube Material : SS 316
    • End Connection : Flange/Wafer
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Accuracy : ± 1% FSD Optional: ±0.5% FSD
    • Repeatability : 0.3%
    • Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC & 24 VDC
    • Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65
    • Protection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.

    Electro Magnetic Flow Meter

    Request Callback

    ₹ 18000 / Piece Get Latest Price

    Product Brochure
    Pipe Size1 Inch
    MaterialStainless Steel
    DisplayDigital
    Model Name/NumberFlowMag900
    Connection25 NB
    Flow Range0.9 - 9 m3/hr
    Accuracy0.5FSD
    Process TemperatureMax. 150 C
    Country of OriginMade in India
    Nominal Diameter15 to 1400 mm
    Process PressureMax. 25 kg/cm 2
    Brand of the ProductFlowtech
    Application MediaWater
    Usage/ApplicationETP

    Minimum order quantity: 1 Piece

    Flowtech Make Electro magnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

    Working Principle:
    • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

    Applications:
    • Scientific laboratory
    • Research centres
    • Chemical industries

    Specifications:

    • Nominal Dia (mm) : 15 to 1200mm
    • Material of Construction : MS, SS 304, SS 316 SS 316L
    • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
    • Process Pressure : Max. 25 kg/cm2
    • Process Temperature : Max. 150C
    • End Connection : Flange/Wafer/TC END
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
    • Accuracy : ± 1% FSD Optional: ±0.5% FSD
    • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC 24 VDC
    • Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65
    • Protection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.

    Boiler Feed Water Flow Meter

    Request Callback

    ₹ 18000 / Piece Get Latest Price

    Product Brochure
    Usage/ApplicationIndustrial
    Line Size25 NB TO 600 NB
    BrandFlowtech
    DisplayDigital
    Accuracy+- 1% FSD
    Process PressureMax. 25 kg/cm2
    Process TemperatureMax. 150 Deg C

    Minimum order quantity: 1 Piece

    Flowtech Make Electromagnetic Flow Boiler Feed Water Meter Are Intended For Measuring Flow Of Electrically Conductive Liquids In Closed Pipe Lines Where The Magnetic Flux Permeates The Entire Cross Sectional Area Of The Liquids Flow. Electromagnetic Flow Meters Measure Electromotive Forces To Determine Liquids Velocity Using Faraday’s Law Of Electromagnetic Induction And Compute The Flow Rate Using Equation Of Conductive Liquids Having Minimum Conductivity Of 5 Micro Siemens / Cm And Are Relatively Immune To The Effects Of Temperature , Pressure , Viscosity & Density Of The Flowing Liquid.

    Working Principle:
    • This Is Working On The Principal Of Faraday`s Law Which States That When A Conductor Moves Through A Magnetic Field Of A Given Strength A Voltage Is Produced In The Conductor And Proportion To The Relative Velocity Between The Conductor And The Magnetic Field.

    Technical Detail:
    • Nominal Dia (mm) : 15 to 1200mm
    • Material of Construction : MS, SS 304, SS 316 & SS 316L
    • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Flow Tube Material : SS 316
    • End Connection : Flange/Wafer/TC END
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC & 24 VDC Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65
    • Protection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.

    Digital Electromagnetic Flow Meter

    Request Callback

    ₹ 18000 / Piece Get Latest Price

    Product Brochure
    ModelEMFM-99
    BrandFlowtech
    Application MediaWater, Any Liquid
    DisplayDigital
    ConnectivityRS485, USB
    Meter TypeElectronics

    Minimum order quantity: 1 Piece

    FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.
     
    Working Principle:

    This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

    Applications:

    • Scientific laboratory
    • Research centres
    • Chemical industries

    Specifications:

    • Nominal Dia (mm) : 15 to 600
    • Material of Construction : MS, SS 304, SS 316 SS 316L
    • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
    • Process Pressure : Max. 25 kg/cm2
    • Process Temperature : Max. 150C
    • Flow Tube Material : SS 316
    • End Connection : Flange/Wafer
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
    • Accuracy : ± 1% FSD Optional: ±0.5% FSD
    • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC 24 VDC
    • Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65
    • Protection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.

    Flow Meter with Data Acquisition Software

    Request Callback

    ₹ 21600 / Piece Get Latest Price

    Product Brochure
    BrandFlowtech
    Application MediaWater
    Line Size25 NB TO 600 NB
    Process PressureMax. 25 kg/cm2
    Process TemperatureMax. 150 Deg C

    Minimum order quantity: 1 Piece

    Working Principle:

    This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

    Applications:

    • Scientific laboratory
    • Research centres
    • Chemical industries

    Specifications:

    • Nominal Dia (mm): 15 to 600
    • Material of Construction: MS, SS 304, SS 316 & SS 316L
    • Process Pressure: Max. 25 kg/cm2
    • Process Temperature: Max. 150C
    • Nominal Dia (mm) : 15 to 400
    • Material of Construction : MS, SS 304, SS 316 & SS 316L
    • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Flow Tube Material : SS 316
    • End Connection : Flange/Wafer/TC END
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Accuracy : ± 1% FSD Optional: ±0.5% FSD
    • Repeatability : 0.3%
    • Display : 2 Line Alfa Numeric LCD
    • Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC & 24 VDC
    • Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65P
    • rotection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.

    Data Acquisition Software Electromagnetic Flow Meter

    Request Callback

    ₹ 21600 / Piece Get Latest Price

    Product Brochure
    Application MediaAny Liquid
    BrandFlowtech
    ApplicationWater
    Process TemperatureMax. 150 Deg C
    Process PressureMax. 25 kg/cm2
    Nominal Diameter15 to 600 mm

    Minimum order quantity: 1 Piece

    Working Principle:
    • Data Acquisition Software Electromagnetic Flow Meter This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

    Applications:
    • Scientific laboratory
    • Research centres
    • Chemical industries
    Specifications:
    • Material of Construction : MS, SS 304, SS 316 & SS 316L
    • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Accuracy : ± 1% FSD Optional: ±0.5% FSD
    • Repeatability : 0.3%
    • Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC & 24 VDC
    • Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65
    • Protection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.

    Data Acquisition Software Flow Meter

    Request Callback

    ₹ 21600 / Set Get Latest Price

    Product Brochure
    ApplicationIndustrial
    Channel SupportUpto 8 Channel
    Sampling RateUpto 10 kSps
    Application MediaWater
    Signal TypeDigital
    InterfaceUSB, WiFi
    OS SupportWindows
    BrandFlowtech
    Process PressureMax. 25 kg/cm2
    Flow range3 to 1271 m3/hr
    Process TemperatureMax. 150 Deg C
    Nominal Diameter15 to 600 mm

    Minimum order quantity: 1 Set

    Data Acquisition Software Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

    Working Principle:
    • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

    Applications:
    • Scientific laboratory
    • Research centres
    • Chemical industries

    Specifications:
    • Material of Construction: MS, SS 304, SS 316 & SS 316L
    • Material of Construction : MS, SS 304, SS 316 & SS 316L
    • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Flow Tube Material : SS 316
    • End Connection : Flange/Wafer
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Accuracy : ± 1%
    • FSD Optional: ±0.5% FSD
    • Repeatability : 0.3%
    • Display : 2 Line Alfa Numeric LCD
    • Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC & 24 VDC
    • Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65
    • Protection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.

    Flow Meter with Data Acquisition Software

    Request Callback

    ₹ 21600 / Piece Get Latest Price

    Product Brochure
    Application MediaAny Liquid
    BrandFlowtech
    Process PressureMax. 25 kg/cm2
    Process TemperatureMax. 150 Deg C
    Nominal Diameter15 to 600 mm

    Minimum order quantity: 1 Piece

    Working Principle:
    • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

    Applications:
    • Scientific laboratory
    • Research centres
    • Chemical industries

    Specifications:
    • Material of Construction: MS, SS 304, SS 316 & SS 316L
    • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Flow Tube Material : SS 316
    • End Connection : Flange/Wafer
    • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
    • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Accuracy : ± 1% FSD Optional: ±0.5% FSD
    • Repeatability : 0.3%
    • Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
    • Display Unit : Standard Unit in M3, Litre
    • Power Supply : 230 VAC, 110 VAC & 24 VDC
    • Output : Std. 4 – 20 mA
    • Protection Class for Sensor : IP 65
    • Protection Class for Transmitter : IP 65
    • Cable Length for Remote : 10 meters
    • Installation : Inline Flange Type.
    X

    Contact Us

    Nilesh Shah (Director)
    Flowtech Measuring Instrument Private Limited
    900/2/B, NR. Pakona Engineering, Gidc Makarpura
    Vadodara - 390010, Gujarat, India

    Get Directions
    Send Email
    Share: