Oil Flow Meters

Leading Manufacturer of edible oil flow meter and oil flow meters from Vadodara.

Edible Oil Flow Meter

Request Callback

₹ 16200 / Piece Get Latest Price

Product Brochure
Application MediaOil / Diesel
MaterialStainless Steel
Model Name/NumberFMIPL-DOGFM
Flow Range50 - 50000 LPH
DisplayRemote
Operating Temperature40 Deg C
Operating Pressure5 kg/cm2
Line Size1/4" to 3"
Accuracy0.5% FSD
Power230 V AC / 24 V DC

Minimum order quantity: 1 Piece

Technical Data Sheet

Material of construction :

Enclosure: Aluminum anodize/S.S-304/S.S-316
Rotor: Aluminum anodize/S.S-316/PPS
O-ring: NBR/Viton
Shaft: Hard Stainless Steel-316 Accuracy (standard installation position) : ±1% RS /0.15% FSD Repeatability : 0.1%.
Maximum working pressure: 5 MPa for aluminum body, 25 MPa for S.S body, above 250 bars please Contact Company.
Fluid & Ambient temperature: -40 to 80°C
Power voltage: Battery operated
Connection: Thread (M/F) or Flange.
Connection Size : 1/4" to 3" 
Flow Range : 50 LPH TO 50000 LPH


Application :

Aluminum body and rotor: Flow measurements of kerosene, Gasoline, diesel, light oil, heavy oils’. Body and rotor: Flow measurements of Pharmaceutical drug, food oil, and all application.

Calibration process :

*Calibrated each flow sensor with three pressure point : 0.5,4 and 25 bar,
*All pressure calculate pulse/litter at : 25%, 50%, 75% and 100% flow rate
*Calibrated with pure diesel.

1) Pulse Output Sensor :
Power voltage: 12 V DC
Output signal: NPN open connector
Output: High electric level: High than 8 VDC (input voltage 12 VDC) Low electric level: lower than 0.8 VDC (input voltage 12 VDC)  

3) Display with 4 to 20 mA
Output Power voltage: 24 V DC Output signal: 4 TO 20 mA 

Oil Flow Meters

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaOil
Model Name/NumberFMIPL-DOGFM-025
Flow Range400 - 4000 LPH
DisplayRemote
Operating TemperatureAmbient
Operating Pressure5 kg/cm2
Line Size25 NB

Minimum order quantity: 1 Piece

Technical Data Sheet

Material of construction :

Enclosure: Aluminum anodize/S.S-304/S.S-316
Rotor: Aluminum anodize/S.S-316/PPS
O-ring: NBR/Viton
Shaft: Hard Stainless Steel-316 Accuracy (standard installation position) : ±1% RS /0.15% FSD Repeatability : 0.1%.
Maximum working pressure: 5 MPa for aluminum body, 25 MPa for S.S body, above 250 bars please Contact Company.
Fluid & Ambient temperature: -40 to 80°C
Power voltage: Battery operated
Connection: Thread (M/F) or Flange.
Connection Size : 1/4" to 3" 
Flow Range : 50 LPH TO 50000 LPH


Application :

Aluminum body and rotor: Flow measurements of kerosene, Gasoline, diesel, light oil, heavy oils’. Body and rotor: Flow measurements of Pharmaceutical drug, food oil, and all application.

Calibration process :

*Calibrated each flow sensor with three pressure point : 0.5,4 and 25 bar,
*All pressure calculate pulse/litter at : 25%, 50%, 75% and 100% flow rate
*Calibrated with pure diesel.

1) Pulse Output Sensor :
Power voltage: 12 V DC
Output signal: NPN open connector
Output: High electric level: High than 8 VDC (input voltage 12 VDC) Low electric level: lower than 0.8 VDC (input voltage 12 VDC)  

3) Display with 4 to 20 mA
Output Power voltage: 24 V DC Output signal: 4 TO 20 mA 
X

Contact Us

Nilesh Shah (Director)
Flowtech Measuring Instrument Private Limited
900/2/B, NR. Pakona Engineering, Gidc Makarpura
Vadodara - 390010, Gujarat, India

Get Directions
Send Email
Share: