Magnetic Flow Meters

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service.


The electromagnetic flow meter is an instrument for measuring the flow of conductive fluid using Faraday's electromagnetic induction law, and consequently the fluid must be electrically conductive. As illustrated below a magnetic field with density B - perpendicular to the direction of flow - stretches across a fluid flowing within an electrically isolated pipe.

The magnetic flux will induce a voltage difference (E) that can be measured between two electrodes arranged perpendicular to the direction of flow and themagnetic field.The voltage is proportionalto the velocity (V) ofthe fluid.

Electromagnetic flow meters may have eitherDirect Current(DC) orAlternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due toelectro-chemical polarization between the electrodes and the fluid. The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of bothDC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.

The pressure loss can easily be determined,ifthe nominal pipediameter is greater than the Flowtech flow sensor. See the diagram below.

According to the type and size of the flow sensor, the measuring accuracy will be better than ± 0.5%, provided that the flow sensor has the correct dimension.

The flowsensor shouldbe selected so the flowvelocity through the sensor will be between 0.5 to 5.0 m/s. Flowtech recommends that flow velocities in tubes are kept between 1 – 3 m/s for reliable and safe operation.

 

Digital Flow Meter With Totalizer

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaWater
Operating Temperature100 Deg C
Line Size2 inch
Accuracy0.5% FSD
Flow Range4 - 40 m3/hr
ConnectivityRS485
Display TypeDigital
Operating Pressure5 kg/cm2
MaterialCS
BrandFlowtech
Country of OriginMade in India
Nominal Diameter15 to 400 mm
Process TemperatureMax. 150 deg C
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Description:

  • Flowtech Make Electromagnetic Digital Flow Meter Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.


Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Technical Detail:

  • Nominal Dia (mm) : 15 to 1600mm
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘C’, & Tantalum
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  •  Optional: ±0.5% FSD
  • Repeatability : 0.3%Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 30 meters
  • Installation : Inline Flange Type.

Magnetic Digital Water Flow Meter For Borewell As Per CGWA

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaWater
Usage/ApplicationETP
BrandFlowtech
DisplayDigital
ConnectivityRS485
Process PressureMax. 25 kg/cm 2
Process TemperatureMax 150 Deg C
Material GradeSS304
Nominal Diameter15mm to 1000 mm

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.

The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.




Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries


Specifications:

  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1000mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer/BSP
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Digital Magnetic Flow Meter

Request Callback

₹ 16200 / Piece Get Latest Price

Product Brochure
Application MediaWater
Operating Temperature150 Deg C
Line Size1 inch
Flow Range0.9 - 9 m3/hr
Accuracy0.5 %
Display TypeDigital
Operating Pressure5 kg/cm2
MaterialCS / MS
BrandFlowtech
Country of OriginMade in India
Process TemperatureMax. 150 Deg C
Process PressureMax. 25 kg/cm 2
Nominal Diameter15 to 400 mm

Minimum order quantity: 1 Piece

Description:

  • Flowtech Make Digital Magnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.


Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Technical Detail:

  • Material of Construction : MS, SS 304, SS 316 SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Flow Tube Material : SS 316
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD.
  • Repeatability : 0.3%
  • Display : 2 Line Alfa Numeric LCD
  • Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters.
  • Installation : Inline Flange Type.

Electromagnetic Flow Sensor Mag Meter

Request Callback

₹ 25200 / Piece Get Latest Price

Product Brochure
Pipe Size6 Inches
Application MediaWater
Usage/ApplicationWater
BrandFlowtech
DisplayDigital
Model Name/NumberFLOWTECH
ConnectivityRS485
Accuracy0.5 %
Country of OriginMade in India
Nominal Diameter15 to 1200 mm
Process PressureMax. 25 kg/cm 2
Process TemperatureMax. 150 deg C

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.

The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.




Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries


Specifications:

  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1200mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer/BSP
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Slurries & Pastes Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationWater
Application MediaWater
BrandFlowtech
TypeFlow Meter
Model Name/NumberFMIPL-EMFM-108
Connection15 NB to 1200 NB Available
Accuracy+/- 0.5 - 1% FSD
Process TemperatureMax. 150 Deg C
Nominal Diameter15 to 400 mm
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Flowmeter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity & density of the flowing liquid.

Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Specifications:

  • Nominal Dia (mm) : 15 to 1200mm
  • Material of Construction : MS, SS 304, SS 316 SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Process Temperature : Max. 150 Deg C
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 30 meters
  • Installation : Inline Flange Type.

Pulse Output Electromagnetic Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Usage/ApplicationWater
Application MediaWater
BrandFlowtech
Pipe Size8 Inches
TypeFlow Meter
Model Name/NumberFMIPL-EMFM-108
Connection15 NB to 1200 NB Available
Process TemperatureMax. 150 Deg C
Nominal Diameter15 NB to 1200 NB Available
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.
 
Working Principle:

This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:

  • Nominal Dia (mm) : 15 to 1200
  • Material of Construction : MS, SS 304, SS 316 SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Process Temperature : Max. 150C
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD
  • Repeatability : 0.3% Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters
  • Installation : Inline Flange Type.

Full Bore Type Electromagnetic Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaWater
Usage/ApplicationWater
BrandFlowtech
DisplayDigital
Model Name/NumberFMIPL-EMFM-108
Line Size2 inch
Power Supply230 V AC & 24 V DC
Connection15 NB TO 1200 NB
Accuracy0.5% FSD
Country of OriginMade in India
Process PressureMax. 25 kg/cm 2
Nominal Diameter15 to 1200 mm
Process TemperatureMax. 150 deg C

Minimum order quantity: 1 Piece

  • Product Description:

    The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

    Measurement : 

    Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


    Working Principle:

    • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


    Applications:

    • Scientific laboratory
    • Research centres
    • Chemical industries


    Specifications:

    • Material of Construction: MS, SS 304, SS 316 & SS 316L
    • Process Pressure: Max. 25 kg/cm2
    • Process Temperature: Max. 150C
    • Nominal Dia (mm): 15 to 1400mm
    • Material of Construction: MS, SS 304, SS 316 & SS 316L
    • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
    • Process Pressure: Max. 25 kg/cm2
    • Process Temperature: Max. 150C
    • Flow Tube Material: SS 316
    • End Connection: Flange/Wafer
    • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF 
    • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
    • Accuracy: ± 1%
    • FSD Optional: ±0.5% FSD
    • Repeatability: 0.3%
    • Display: 2 Line Alfa Numeric LCD
    • Display Version: Integral /Remote
    • Display Unit: Standard Unit in M3, Litre
    • Power Supply: 230 VAC, 110 VAC & 24 VDC
    • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
    • Protection Class for Sensor: IP 65
    • Protection Class for Transmitter: IP 65
    • Cable Length for Remote: 30meters
    • Meters Installation: Inline Flange Type.

Electromag Full Bore Magnetic Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaWater
Usage/ApplicationETP
BrandFlowtech
Operating Temperature100 Deg C
DisplayDigital
Line Size1 inch
Connection15 NB TO 1000 NB
Display TypeDigital
Accuracy0.5 %
Process TemperatureMax. 150 Deg C
Nominal Diameter15 to 1200 mm
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.

The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.




Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries


Specifications:

  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1200mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer/BSP
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Electromagnetic Flow Meter with Telemetry System

Request Callback

₹ 21600 / Piece Get Latest Price

Product Brochure
MaterialStainless Steel
Usage/ApplicationIndustrial
BrandFlowtech
Application MediaWater
DisplayDigital
Model Name/NumberFMIPL-EMFM-108
Connection15 NB to 1400 NB
Flow RangeAs per Connection
Accuracy+/-1% on Current Reding
Electrode MaterialSS.316, SS.316L, HESTALLO-C, TANTALAM
Country of OriginMade in India
Pressure25 Kg/CM2
Available MaterialSS-316 / SS-304 / P.P/ P.T.F.E. Lined Construction

Minimum order quantity: 1 Piece

Flowtech Make Electromagnetic Water Digital Flow MeterAre Intended For Measuring Flow Of Electrically Conductive Liquids In Closed Pipe Lines Where The Magnetic Flux Permeates The Entire Cross Sectional Area Of The Liquids Flow. Electromagnetic Flow Meters Measure Electromotive Forces To Determine Liquids Velocity Using Faraday’s Law Of Electromagnetic Induction And Compute The Flow Rate Using Equation Of Conductive Liquids Having Minimum Conductivity Of 5 Micro Siemens / Cm And Are Relatively Immune To The Effects Of Temperature , Pressure , Viscosity & Density Of The Flowing Liquid.

Working Principle:

  • This Is Working On The Principal Of Faraday`s Law Which States That When A Conductor Moves Through A Magnetic Field Of A Given Strength A Voltage Is Produced In The Conductor And Proportion To The Relative Velocity Between The Conductor And The Magnetic Field.


Technical Detail:

  • Nominal Dia (mm) : 15 to 1400NB
  • Material of Construction : MS, SS 304, SS 316 & SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Flow Tube Material : SS 316
  • End Connection : Flange/Wafer/TC END
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Repeatability : 0.3%Display : 2 Line Alfa Numeric LCD Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC & 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters
  • Installation : Inline Flange Type.

Corrosive Liquid Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Pipe Size12 Inches
MaterialMild Steel
Usage/ApplicationWater
BrandFlowtech
DisplayDigital
Model Name/NumberFlowMag900
Connection25 NB
Flow Range127 - 1271 M3/HR
Accuracy+-1 %
Process TemperatureMax. 150 deg C
Country of OriginMade in India
Repeatability0.3%
Nominal Diameter300 mm
Process PressureMax. 25 kg/cm 2

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 

Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries


Specifications:

  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150 Deg C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF 
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • Meters Installation: Inline Flange Type.

Flame Proof Electromagnetic Flow Meter

Request Callback

₹ 22500 / Piece Get Latest Price

Product Brochure
Pipe Size1 Inch
Application MediaAny Liquid
MaterialStainless Steel
Usage/ApplicationWater
BrandFlowtech
DisplayDigital
Model Name/NumberFlowMag900
Connection25 NB ASA 150 # RF
Line Size15 NB to 1400 NB
Flow Range0.9 - 9 M3/HR
Accuracy0.5% FSD.
Country of OriginMade in India
Process PressureMax. 25 kg/cm 2
Process TemperatureMax. 150 Deg C

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 
Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.

Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Applications:

  • Scientific laboratory
  • Research centres
  • Chemical industries


Specifications:

  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150 Deg C
  • Nominal Dia (mm): 15 to 1400mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • metersInstallation: Inline Flange Type.

Digital Water Flow Meter Applications

Water flow meters can measure cold water, hot water, clean water, dirty water and slurries


Indian Market

Indian States: Telangana, Tamil Nadu, Mizoram, Jharkhand, Arunachal Pradesh, Manipur, Tripura, Kerala, Gujarat, Maharashtra, Madhya Pradesh, Rajasthan, Uttar Pradesh, Orissa, Uttarakhand, Assam, Sikkim, Nagaland, Chhattisgarh, Tamil Nadu, Jammu and Kashmir, Haryana, West Bengal, Goa, Delhi, Bihar, Punjab, etc.

International Market

Asian Countries: Indonesia, Thailand, Malaysia, Singapore, Nepal, Bangladesh, etc
Europe: France, Poland, Spain, etc
Gulf Countries: Saudi Arabia, United Arab Emirates,etc..

Online Effluent Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaWater
BrandFlowtech
Usage/ApplicationAutomotive
Operating Temperature50 Deg C
Accuracy+- 1% FSD Optional: +-0.5% FSD.
Display TypeDigital
MaterialStainless Steel
Nominal Diameter15 to 600 mm
Process PressureMax. 25 kg/cm 2
Process TemperatureMax. 150 Deg C

Minimum order quantity: 1 Piece

Description:

  • Flowtech Make Electromagnetic
  • Digital Water Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.

 

Working Principle:

  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.


Technical Detail:

  • Nominal Dia (mm) : 15 to 600
  • Material of Construction : MS, SS 304, SS 316 SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Process Pressure : Max. 25 kg/cm2
  • Flange- Standard : ANSI B 16.5 150 #RF / 300 # RF
  • Measuring Range : 0.5 m/sec for Minimum 5m/sec for Maximum
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD.
  • Repeatability : 0.3%
  • Display : 2 Line Alfa Numeric LCD
  • Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA / RS 485
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters.
  • Installation : Inline Flange Type

Electromagnetic Flowmeter RS485

Request Callback

₹ 36000 / Piece Get Latest Price

Product Brochure
BrandFlowtech
Pipe Size12 Inches
TypeFlow Meter
DisplayDigital
Model Name/NumberFMIPL-EMFM-108
Power Supply230 V AC / 24 V DC
Connection15 NB to 1200 NB
ConnectivityRS485
Accuracy0.5% FSD
Process TemperatureMax. 150 deg C
Country of OriginMade in India
Nominal Diameter15 to 1200 mm
Process PressureMax. 25 kg/cm 2
Application MediaWater
Usage/ApplicationETP

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 

Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1200mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF 
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • Meters Installation: Inline Flange Type.

Mag Flow Meter

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
BrandFlowtech
Pipe Size1 Inch
Application MediaWater
MaterialMild Steel
DisplayDigital
Power Supply230 V AC / 24 V DC
Model Name/NumberFlowMag900
Connection25 NB
Accuracy0.5 % FSD
Flow Range0.9 - 9 m3/hr
Country of OriginMade in India
ApplicationsScientific laboratory, Research centres, Chemical industries
Available Lined ConstructionSS-316 / SS-304 / P.P. / P.T.F.E

Minimum order quantity: 1 Piece

Product Description:

The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service. 

Measurement : 

Electromagnetic flow meters may have either Direct Current (DC) or Alternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due to electro-chemical polarization between the electrodes and the fluid.The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of both DC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.


Working Principle:
  • This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.

Applications:
  • Scientific laboratory
  • Research centres
  • Chemical industries

Specifications:
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Nominal Dia (mm): 15 to 1600mm
  • Material of Construction: MS, SS 304, SS 316 & SS 316L
  • Electrode Material: SS 316, SS 316L, Hastelloy ‘c’, & Tantalum
  • Process Pressure: Max. 25 kg/cm2
  • Process Temperature: Max. 150C
  • Flow Tube Material: SS 316
  • End Connection: Flange/Wafer
  • Flange- Standard: ANSI B 16.5 150 #RF / 300 # RF 
  • Measuring Range: 0.5 m/sec for Minimum & 5m/sec for Maximum
  • Accuracy: ± 1%
  • FSD Optional: ±0.5% FSD
  • Repeatability: 0.3%
  • Display: 2 Line Alfa Numeric LCD
  • Display Version: Integral /Remote
  • Display Unit: Standard Unit in M3, Litre
  • Power Supply: 230 VAC, 110 VAC & 24 VDC
  • Output: Std. 4 – 20 mA / RS 485 / PULSE / HART
  • Protection Class for Sensor: IP 65
  • Protection Class for Transmitter: IP 65
  • Cable Length for Remote: 30meters
  • Meters Installation: Inline Flange Type.

Flow Measurement Instruments

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Application MediaAny Liquid
BrandFlowtech
Process PressureMax. 25 kg/cm 2
Accuracy0.5 %
Nominal Diameter15 to 400 mm
Process TemperatureMax. 150 Deg C

Minimum order quantity: 1 Piece

Water Flow Measurement Instruments works on a Faraday principle that states when a conductor moves through a magnetic field, a potential difference is set up across the conductor and is in proportion to the relative velocity between the conductor and magnetic field.
It is designed to measure the flow of current conductive liquids in closed pipelines where the magnetic flux permeates the whole cross-sectional area of the flowing liquids. Electromagnetic flow meters measure electromotive forces to measure liquid velocity and calculate the flow rate. They withstand wide temperature limits, pressures, viscosities and densities of the running liquid.
Our flow meter has a compact design and is internationally appreciated for being lightweight. It enables easy operations and is available at reasonable price. It is highly demanded across the country.

Effluent flow meter comprises of remote transmitter, compact or remote mounted dual display, flanges and power supply.
FeaturesLight weightHigher qualityCompact structureLow costEasy to installIn-house calibrationLatest technologyEarth ring is not neededApplicationsScience labsResearch hubsChemical plants ETPWaste water treatment Sewage TreatmentTechnical.

Technical Detail:

  • Material of Construction : MS, SS 304, SS 316 SS 316L
  • Electrode Material : SS 316, SS 316L, Hastelloy ‘c’, Tantalum
  • Flow Tube Material : SS 316
  • Accuracy : ± 1% FSD Optional: ±0.5% FSD.
  • Repeatability : 0.3%
  • Display : 2 Line Alfa Numeric LCD
  • Display Version : Integral /Remote
  • Display Unit : Standard Unit in M3, Litre
  • Power Supply : 230 VAC, 110 VAC 24 VDC
  • Output : Std. 4 – 20 mA
  • Protection Class for Sensor : IP 65
  • Protection Class for Transmitter : IP 65
  • Cable Length for Remote : 10 meters.
  • Installation : Inline Flange Type
X

Contact Us

Nilesh Shah (Director)
Flowtech Measuring Instrument Private Limited
900/2/B, NR. Pakona Engineering, Gidc Makarpura
Vadodara - 390010, Gujarat, India

Get Directions
Send Email
Share: