The Electromagnetic Flowmeter or Mag Meters are suitable for flow measurement in all kinds of conductive fluids, and it is especially suited for flow measurement of Water, Waste Water, Sludge and other fluids containing particles. The flow meter is easy to install and put to service.
The electromagnetic flow meter is an instrument for measuring the flow of conductive fluid using Faraday's electromagnetic induction law, and consequently the fluid must be electrically conductive. As illustrated below a magnetic field with density B - perpendicular to the direction of flow - stretches across a fluid flowing within an electrically isolated pipe.
The magnetic flux will induce a voltage difference (E) that can be measured between two electrodes arranged perpendicular to the direction of flow and themagnetic field.The voltage is proportionalto the velocity (V) ofthe fluid.
Electromagnetic flow meters may have eitherDirect Current(DC) orAlternating Current (AC) excitation. When systems are AC excited, electrostatic and/or electromagnetic noise may influence the measurements. A DC excited system however, is less sensitive to noise produced by electromagnetic induction, simply because the voltage induced over the electrodes will be a DC voltage. The drawbacks are measurement errors due toelectro-chemical polarization between the electrodes and the fluid. The Electromagnetic Flow Meters are excited by a 2.5 Hz square wave and thereby eliminate the drawbacks of bothDC and AC systems. A microprocessor receives and measures the amplitude of the pulse with a 16 - bit resolution, and converts and displays the result on the display unit.
The pressure loss can easily be determined,ifthe nominal pipediameter is greater than the Flowtech flow sensor. See the diagram below.
According to the type and size of the flow sensor, the measuring accuracy will be better than ± 0.5%, provided that the flow sensor has the correct dimension.
The flowsensor shouldbe selected so the flowvelocity through the sensor will be between 0.5 to 5.0 m/s. Flowtech recommends that flow velocities in tubes are kept between 1 – 3 m/s for reliable and safe operation.
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Flowtech |
Connectivity | RS485 |
Process Pressure | Max. 25 kg/cm 2 |
Process Temperature | Max 150 Deg C |
Material Grade | SS304 |
Nominal Diameter | 15 to 400 mm |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Brand | Flowtech |
Model Name/Number | FMIPL-EMFM-108 |
Usage/Application | Water |
Connection | 15 NB TO 600 NB |
Nominal Diameter | 15 to 400 mm |
Process Pressure | Max. 25 kg/cm 2 |
Process Temperature | Max. 150 deg C |
Description
Working Principle
Technical Detail
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Flowtech |
Application Media | Any Liquid |
Applications | Scientific laboratory, Research centres, Chemical industries |
Suitable for Temperature | Up to 100 Deg C |
Pressure | Up to 3 kg/Cm2 |
Available Lined Construction | SS-316 / SS-304 / P.P. / P.T.F.E |
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Model Name/Number | FMIPL-EMFM-108 |
Brand | Flowtech |
Usage/Application | ETP |
Connection | 15 NB to 600 NB |
Type | Flow Meter |
Connectivity | RS485 |
Process Temperature | Max. 150 deg C |
Nominal Diameter | 15 to 600 mm |
Process Pressure | Max. 25 kg/cm 2 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Operating Temperature | 150 Deg C |
Display Type | Digital |
Accuracy | 0.5 % |
Brand | Flowtech |
Nominal Diameter | 15 to 400 mm |
Process Pressure | Max. 25 kg/cm 2 |
Process Temperature | Max. 150 Deg C |
Description:
Working Principle:
Technical Detail:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Operating Temperature | 50 Deg C |
Accuracy | +- 1% FSD Optional: +-0.5% FSD. |
Display Type | Digital |
Usage/Application | Automotive |
Material | Stainless Steel |
Brand | Flowtech |
Nominal Diameter | 15 to 600 mm |
Process Pressure | Max. 25 kg/cm 2 |
Process Temperature | Max. 150 Deg C |
Description:
Working Principle:
Technical Detail:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Connectivity | RS485 |
Brand | Flowtech |
Nominal Diameter | 15 to 400 mm |
Process Pressure | Max. 25 kg/cm 2 |
Process Temperature | Max. 150 deg C |
Description:
Working Principle:
Technical Detail:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Any Liquid |
Brand | Flowtech |
Process Pressure | Max. 25 kg/cm 2 |
Accuracy | 0.5 % |
Nominal Diameter | 15 to 400 mm |
Process Temperature | Max. 150 Deg C |
Technical Detail:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Model Name/Number | FMIPL-EMFM-108 |
Usage/Application | Water |
Connection | 15 NB to 600 NB |
Type | Flow Meter |
Accuracy | +/- 0.5 - 1% FSD |
Brand | Flowtech |
Process Temperature | Max. 150 Deg C |
Nominal Diameter | 15 to 400 mm |
Process Pressure | Max. 25 kg/cm 2 |
Description:
Working Principle:
Technical Detail:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Brand | Flowtech |
Material | Stainless Steel |
Model Name/Number | FMIPL-EMFM-108 |
Connection | 15 NB to 600 NB |
Display | Digital |
Flow Range | As per Connection |
Accuracy | +/-1% on Current Reding |
Communication | 4 - 20 mA / RS 485 MODBUS / PULSE |
Electrode Material | SS.316, SS.316L, HESTALLO-C, TANTALAM |
Usage/Application | Industrial |
Pressure | 25 Kg/CM2 |
Available Material | SS-316 / SS-304 / P.P/ P.T.F.E. Lined Construction |
Flowtech Make Electromagnetic Water Digital Flow MeterAre Intended For Measuring Flow Of Electrically Conductive Liquids In Closed Pipe Lines Where The Magnetic Flux Permeates The Entire Cross Sectional Area Of The Liquids Flow. Electromagnetic Flow Meters Measure Electromotive Forces To Determine Liquids Velocity Using Faraday’s Law Of Electromagnetic Induction And Compute The Flow Rate Using Equation Of Conductive Liquids Having Minimum Conductivity Of 5 Micro Siemens / Cm And Are Relatively Immune To The Effects Of Temperature , Pressure , Viscosity & Density Of The Flowing Liquid.
Working Principle:
Technical Detail:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Model Name/Number | FMIPL-EMFM-108 |
Brand | Flowtech |
Usage/Application | ETP |
Connection | 15 NB TO 600 NB |
Type | Flow Meter |
Usage | Industrial |
Max. Pressure | 25 Bar |
Power Supply | 24 V DC -230 V AC |
Operation Principle:
FLOWTECH Make Electromagnetic Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.
Working Principle:
This is working on the principal of faraday`s law which states that when a conductor moves through a magnetic field of a given strength a voltage is produced in the conductor and proportion to the relative velocity between the conductor and the magnetic field.
Applications:
Specifications:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Model Name/Number | FMIPL-EMFM-108 |
Brand | Flowtech |
Usage/Application | ETP |
Connection | 15 NB to 600 NB |
Type | Flow Meter |
Process Temperature | Max. 150 deg C |
Nominal Diameter | 15 to 600 mm |
Process Pressure | Max. 25 kg/cm 2 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Flowtech |
Connectivity | RS485 |
Accuracy | 1 % |
Nominal Diameter | 15 to 400 mm |
Process Pressure | Max. 25 kg/cm 2 |
Process Temperature | Max. 150 deg C |
Description:
Working Principle:
Technical Detail
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Accuracy | +-1 % |
Brand | Flowtech |
Process Temperature | Max. 150 deg C |
Repeatability | 0.3% |
Nominal Diameter | 15 to 400 mm |
Process Pressure | Max. 25 kg/cm 2 |
Description:
Working Principle:
Technical Detail:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Usage/Application | ETP |
Connection | 15 NB TO 600 NB |
Accuracy | 0.5 % |
Brand | Flowtech |
Process Temperature | Max. 150 Deg C |
Nominal Diameter | 15 to 400 mm |
Process Pressure | Max. 25 kg/cm 2 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Application Media | Water |
Usage/Application | ETP |
Line Size | 15 NB to 600 NB |
Brand | Flowtech |
Country of Origin | Made in India |
Process Pressure | Max. 25 kg/cm 2 |
Process Temperature | Max. 150 Deg C |
Flowtech Make Electromagnetic Water Flow Meter are intended for measuring flow of electrically conductive liquids in closed pipe lines where the magnetic flux permeates the entire cross sectional area of the liquids flow. Electromagnetic flow meters measure electromotive forces to determine liquids velocity using Faraday’s law of electromagnetic induction and compute the flow rate using equation of conductive liquids having minimum conductivity of 5 micro Siemens / cm and are relatively immune to the effects of temperature , pressure , viscosity density of the flowing liquid.
Working Principle
Technical Detail:
Additional Information: